Industrial Foundation Karst Detection
Multi-electrode resistivity array at 5-meter electrode spacing detected sub-surface dissolution voids beneath a planned 14-hectare chemical processing plant, enabling targeted grouting prior to foundation pouring.
Mine Tailings Facility Seepage Profiling
Cascade Rail Tunnel Portal Delineation
Installed semi-permanent monitoring lines combining spontaneous potential and induced polarization to locate pore-water infiltration paths through an earth-fill retention embankment without invasive trenching.
Executed 4.2 line-kilometers of high-resolution electrical resistivity tomography and seismic refraction across fractured metamorphic granite. Mapped shear fault zones down to 85 meters depth, resolving structural blind spots between widely spaced exploration boreholes.






Rigorous acquisition under tough conditions
Instrument-grade field operations demand continuous geodetic calibration, disciplined station spacing, and immediate on-site quality control of raw seismic and apparent resistivity readings.
StrataCore reconciled our acoustic velocity anomalies against four confirmation borings, allowing us to redesign tunnel benching and eliminate nearly four hundred thousand dollars in exploratory drilling.
Marcus Vance, PE, Geotechnical Lead, Pacific Rail Infrastructure
Send station coordinates, target geological depths, or site elevation models. Our field desk evaluates modality suitability, line layouts, and required borehole calibration before mobilization.